One of the most important factors in selecting the optimum flat or low-slope commercial roof insulation is designing to the desired thermal efficiency. R-value is a measurement to quantify the insulating properties of a building material. The highest R-valueper inchis the best, and this helps determine flat roof insulation thickness for building regulations. Understanding relative R-values will help rank the comparison of various materials choices.

Let’s take a look at how the most common types of flat roof insulations rank according to R-value.

1. Phenolic Foam Roof Insulation R = Up to 7.5 as reported by various manufacturers

Guide to Commercial Flat Roof Insulation Product Types & R-Values - IKO (2)

Phenolic foam had high reported initial R-values of up to 7.5 per inch, but this product has not been widely produced in the U.S. since the early 90s because of litigation concerning the corrosiveness and leaching acidic impact on metal decks or metal fasteners under certain conditions. Some roof assemblies, especially lightweight concrete decks, may have this insulation still installed.

Currently, a European manufacturer is marketing a reformulation for restricted building materials usage in the USA and Canada. Specifiers can decide if the benefits of a high R-value insulation will outweigh other potential concerns.

2. Polyurethane Roof Insulation R = 7.2

Guide to Commercial Flat Roof Insulation Product Types & R-Values - IKO (3)

Polyurethane in sprayed-on foam is a high R-value choice for flat roof insulations. TheAmerican Chemistry Council Center for the Polyurethanes Industryreports R-values of up to 7.2 per inch. For commercial flat roofing, either 1-component or 2-component spray polyurethane foam is commonly used as well as insulated metal panels for the building envelope. Cold storage buildings with freezers or coolers often utilize polyurethane insulated metal panels.

There are several advantages to polyurethane: structural performance, dimensional stability and moisture resistance. The major benefit of spray polyurethane foam (SPF) is that it can conform to irregular surfaces on a wide variety of substrates. There is typically long-term stability of the R-value as well as high fire resistance. Polyurethane does have a narrower window of application temperature and humidity limitations in some climate conditions.

3. Polyisocyanurate Roof Insulation R = 6.8*

Guide to Commercial Flat Roof Insulation Product Types & R-Values - IKO (4)

Polyisocyanurate(polyiso) is closed-cell foam bonded to various facers, such as glass or foil. The blowing agents used to manufacture the product have evolved over time to meet environmental goals. Many manufacturers certify their EPA-compliant blowing agents as not having any CFCs or HCFCs to meet zero ozone depletion potential (ODP) roof insulation standards.

The polyiso industry has established a standard called “LTTR” — Long Term Thermal Resistance ­— that indicates how polyiso will insulate over time; it is essentially an aged R-value.

As an example, theR-valueof a foil-faced polyisocyanurate panel produced with pentane ranges from an initial R-value of 6.8 per inch to 5.7 per inch as projected over time.Polyisocyanurate foam board roof insulationis one of the best roofing insulations and is one of the top choices for very high thermal efficiency. Polyiso is available for flat roof insulation systems, and it also can be supplied as tapered insulation board for flat roofs.

Designers who pursue certifications under green building rating systems, such as LEED®v4, would want to review adding insulation to a flat roof, such as nonhalogenated polyisocyanurate roof insulation. These formulations do not have flame-retardant chemicals that may adversely affect the environment.

Polyiso is the only foam plastic insulation product for direct application to steel decks to achieve FM Approval for Class 1 Roof Systems. It is also classified by UL for direct-to-steel deck insulation under both single-ply andasphaltic roof membranes.

Polyiso roof insulation is also produced at high density to become a much-specified cover board. Cover boards protect the roof assembly from roof traffic, mechanical abuse and hail. Theseroof cover boardsare resilient and lightweight.

ThePolyisocyanurate Insulation Manufacturers Association(PIMA) does outstanding work in researching the latest trends in polyiso advances and is a great support for the insulation industry.

*Initial, not LTTR aged value, to make an effective comparison with other products

4. High-Density Extruded Polystyrene (XPS) Roof Insulation R = 5

Guide to Commercial Flat Roof Insulation Product Types & R-Values - IKO (5)

With an R-value of approximately 5 per inch, extruded polystyrene (XPS) is created utilizing an extrusion process to produce closed-cell rigid foam insulation with polystyrene polymer. Many manufacturers add a dye to the formulation to add a unique colouration, typically pink, green or blue to distinguish the product brand.

Most XPS is used for wall and below-grade applications. For commercial roofing, it is most commonly specified for Inverted Roof membrane Assembly (IRMA) or Protected Membrane Roof (PMR) systems. Extruded polystyrene is usually ranked in the middle of cost vs. R-value in terms of cost/benefit evaluation of flat roofing materials.

It is vulnerable to solvent-based adhesives and hot asphalt, and its use in PMR systems requiring ballast can make structural weight of the assembly an issue.

5. High-Density Expanded Polystyrene (EPS) Roof Insulation R = 4.6

Guide to Commercial Flat Roof Insulation Product Types & R-Values - IKO (6)

Expanded polystyrene (EPS) is made from the same base polystyrene resins as XPS, but the manufacturing process is different, resulting in beads that are formed and cut into different sizes and shapes or molded. High-density products have an approximate R-value of 4.6 as a relative comparison.

Contractors like to install EPS as it can be cut easily to meet site conditions, and it is lightweight. Theoretically, it has a more stable R-value over time as there are no chemical blowing agents that can outgas. There are no current studies that can confirm this attribute.

EPS has several disadvantages, however. It is combustible, will absorb water, can shrink and warp with high temperature exposure, and is not compatible with petroleum-based products, such as solvents, coatings and adhesives. In addition, foot traffic on the roof can damage the material.

6. Glass Fiber and Mineral Fiber Batts and Panels R = Variable by Manufacturer

Guide to Commercial Flat Roof Insulation Product Types & R-Values - IKO (7)

The commercial roofing industry phased out rigid fiberglass two-by-four panels as single-ply roofing systems became a larger share of the market. Soft underfoot, fiberglass was not recommended for EPDM, PVC orTPO systems. Traditionally, fiberglass sheets were used as a substrate for hot roofing systems, and they had several advantages: They provided high fire resistance and flexibility, and they were chemically inert and resistant to mold growth.

There were few suppliers dedicated to market commercial roofing systems with the necessary resources to support various code testing in contemporary assemblies. Currently, fiberglass rolls can be purchased for specialized uses, such as metal building insulations. Additionally, there are formaldehyde-free mineral wool options for certain applications.

7. Perlite Board R = 2.7

Guide to Commercial Flat Roof Insulation Product Types & R-Values - IKO (8)

Considered a “low thermal insulation” in the manufacturing process, it is typically combined with binders and reinforcing cellulosic fibers. In production since the late 1950s, perlite was considered the pioneer environmental flat roof insulation product due to its high recycled content of paper waste, often manufactured with used phone books. It is economical and has a stable R-value. High-density versions of the product can be installed over wide flutes with metal deck spans up to 2 1/2 inches. With hot roofing systems, perlite is available in a number of composite construction boards, including OSB and gypsums.

Perlite boards can rot when wet and need surface treatments or coatings to prevent excessive absorption of asphalt during installation. Again, with the advent of single-ply roofing systems and their increasing specifications, this product is losing favor as a choice in commercial roofing.

R-value is but one of many criteria in the selection of flat roofing insulations for commercial applications. Insulation is just one component in a full roofing assembly. Other determining factors can be:

  1. Compliance with ASHRAE Standard 90.1, International Energy Conservation Code (IECC), International Building Code (IBC), International Green Construction Code (IgCC), Canadian provinces and territory standards.
  2. UL or FM requirements.
  3. ASHRAE Standard 189.
  4. S. Green Building Council LEED Rating System.

For more information on roof insulation, please see ourcomprehensive guide to polyiso insulation.

Guide to Commercial Flat Roof Insulation Product Types & R-Values - IKO (2024)
Top Articles
Latest Posts
Article information

Author: Reed Wilderman

Last Updated:

Views: 6082

Rating: 4.1 / 5 (52 voted)

Reviews: 83% of readers found this page helpful

Author information

Name: Reed Wilderman

Birthday: 1992-06-14

Address: 998 Estell Village, Lake Oscarberg, SD 48713-6877

Phone: +21813267449721

Job: Technology Engineer

Hobby: Swimming, Do it yourself, Beekeeping, Lapidary, Cosplaying, Hiking, Graffiti

Introduction: My name is Reed Wilderman, I am a faithful, bright, lucky, adventurous, lively, rich, vast person who loves writing and wants to share my knowledge and understanding with you.